Why is cement dust different from ordinary dust?
Ordinary dust sits loosely on the glass. Wind, rain or a soft brush moves it. Cement dust is alkaline, and it reacts with water. Dew, a light shower or the wash water itself is enough to start it curing, and over time the glass carries a hard, hazy film.
IEA PVPS (2022) describes the general mechanism, called cementation. Dew dissolves the soluble part of the dust, which then recrystallises and binds particles to the glass in bonds that dry cleaning can’t break. Cement is made to set when it gets wet, so cement dust is the extreme case. Ilse et al. (2019) note that cemented dust, like lichen and fungi, can become practically irremovable.
The loss is real. See Chemitek’s Dubai case.
That makes cement contamination, not ordinary soiling, and the difference decides the fix:
- Soiling is the dust, sand and pollen that build up between cleans, on almost every plant. Solar Wash Protect or Antistatic Solar Armor 2.0 in the normal clean is all it needs. In Chemitek’s field cases, Solar Wash Protect added energy over water-only cleaning at a utility plant in Honduras and 5.1% on a rooftop in India.
- Contamination is cement, limescale from hard water, mineral deposits, metal oxides or lichen. It bonds to the glass and keeps building until it is removed, so the losses are larger. The fix is to remove it, then protect the glass so it doesn’t bond again. These plants usually gain the most.
How do you know it’s cement and not ordinary dust?
Two questions point to a cured deposit:
- Is there a source nearby? Cement works, quarries, precast yards and building sites are the usual culprits. The Chilean carport in Chemitek’s case study sat beside a precast-concrete factory.
- Does a normal wash leave it behind? Loose dust comes off with water and a brush. A cured film doesn’t: in Dubai, fortnightly washing with a rotary brush had failed.
Then confirm it before anyone picks a product. A site soiling assessment identifies the contaminant. Dust analysis is worth doing: in the peer-reviewed Green Energy Park trial in Morocco, analysis of the dust (XRF, FTIR and SEM) found 26–36% calcium oxide (Elamim et al. 2023).
Why doesn’t water remove cement dust?
Because the film isn’t loose dust any more. Water can’t dissolve a cured bond, and pre-wetting works against the fix: Chemitek’s datasheet says to apply Cement Removal Agent to dry modules, because wet glass greatly reduces its effect.
The field record agrees:
- Dubai: fortnightly water cleaning with a rotary brush had failed to remove cured cement dust (Chemitek, with SirajPower).
- Chile: water had failed on a carport beside a precast-concrete factory (Chemitek, with Ecomundo).
- Israel: cleaning by hand with water alone had failed on a 160 kWp plant with cured cement (Chemitek, with Girasol).
Scrubbing harder isn’t the answer either. Abrasive methods damage the anti-reflective coating. Pressure and brush rules are set by the module makers: see warranty-safe methods.
How do you remove cement dust from solar panels safely?
Use a remover made for alkaline deposits, applied exactly as its datasheet says. Chemitek Cement Removal Agent (CRA) reacts with cement dust, stone dust, gypsum and other alkaline deposits, not with the glass, and turns them into particles that rinse off. Chemitek designed it to be gentle on the anti-reflective coating, silicone and aluminium frame. CRA carries letters of conformity from eight module makers; see cleaning and your module warranty.
The method, from Chemitek’s datasheet:
- Test a small area to find the dilution that lifts your film.
- Dilute. Start at 1 kg of CRA to 2 L of water. If that doesn’t lift the film, strengthen to 1:1 or 1:0.5. Neat product is a last resort that Chemitek advises against.
- Apply to dry modules. Don’t pre-rinse; wet glass greatly reduces the effect.
- React and brush. Let it react for a few seconds without drying, then brush it in without adding water.
- Rinse thoroughly with clean water and a brush. Repeat on stubborn areas.
- Protect straight away with Antistatic Solar Armor 2.0 (below).
In the Dubai case, CRA was applied at 1:2, using 500–800 mL of diluted product per panel. Work section by section, so the product never dries before it is brushed and rinsed, and follow the safety data sheet for handling.
Rinse water matters too: hard water leaves scale as it dries. See water quality for solar panel cleaning.
How do you plan cement removal on a large plant?
Treat it as a project, not a wash:
- Map the film. Soiling is not uniform across a site, so find out where the film is heaviest before you order product or set a crew rate. See soiling ratio, rate and loss explained.
- Set the dilution by block. Run a test patch in each area rather than once for the whole plant; the datasheet’s 1:2 is a starting point, not a rule.
- Estimate quantities. The Dubai case used 500–800 mL of diluted CRA per panel at 1:2. At that dilution, one part in three is product. CRA comes in 5 kg, 20 kg and 1,000 kg IBC packs.
- Choose crew and kit. Match brushes and pressure to the module maker’s rules, and plan the order of work so product never dries on the glass.
- Plan the rinse water. It must be clean and, where the supply is hard, softened.
- Measure before and after. Compare treated strings with untreated controls in the same irradiance window, and keep a soiling sensor running to see how fast the glass soils again.
How do you stop cement dust coming back?
Removal resets the glass; it does nothing about tomorrow’s dust. Chemitek pairs CRA with Antistatic Solar Armor 2.0 (ASA 2.0), an antistatic coating that reduces how strongly fine dust clings to the glass.
- ASA 2.0 is dosed into the cleaning water at 1 kg per 1,000 L and applied during a normal clean with rotary brushes, robots or tractor-mounted brushes. There is no separate coating visit and no rinse.
- The first application must leave the glass fully clean, so the coating bonds to bare glass. With a tractor brush, slow down until all the soiling is off.
- Chemitek advises against manual brushing with ASA 2.0 and recommends Solar Wash Protect for manual crews.
- Chemitek states at least 12 months of protection, up to 5% more energy than water-only cleaning and about 50% less cleaning water. See Solar Wash Protect.
On a 160 kWp site in Israel with cured cement, modules coated with ASA after removal still cleaned fully two weeks later, while uncoated modules had cement stuck to them. It is a qualitative result, recorded in photos (Case study: Chemitek (Portugal), with Girasol; see the Israel case).
Coatings don’t work everywhere, though. Short tests of anti-soiling coatings show more than 80% less soiling, but long-term field results are typically 20–50%, and some coatings make soiling worse (Ilse et al. 2019). In the Northern Cape, a hydrophobic coating increased dust soiling (du Plessis et al. 2020). ASA 2.0 is antistatic rather than hydrophobic, but the lesson holds: prove it on your own strings.
What does this mean for a South African plant?
What did field trials measure? Field results live on the case pages: Dubai, the Chile carport, Israel and our North West pilot. Chemitek’s figures are inverter energy over several weeks, and every trial compares treated modules with untreated ones under the same sun, which is what makes them credible.
The Israel result is qualitative: coated modules still cleaned fully two weeks later.
Near a cement works, quarry or building site, we design a Restore → Protect → Maintain programme:
- Restore: Cement Removal Agent, section by section, to take off the cured film.
- Protect: Antistatic Solar Armor 2.0, so new dust bonds less.
- Maintain: Solar Wash Protect 50, with softened water where the cleaning water is hard.
The crew, brushes and dosing equipment are matched to that method: see equipment selection.
Two conditions shape any plan like this. Water: where the cleaning water is hard, every rinse can leave scale, so the Maintain phase uses softened water. Environmental rules: Chemitek has its products’ biodegradability tested to OECD 301F by Portugal’s CVR, and describes Solar Wash Protect as readily biodegradable. Check your own environmental conditions against each product’s safety data sheet.
Plants with a bonded film usually gain the most from the right clean. If yours sits near a cement works, quarry or building site, a measurement and a pilot show what the film is costing and what removes it. For utility-scale and large C&I plants, the pilot is free. If your crews already know the film, order just Cement Removal Agent and follow the method above. See also cement dust on solar panels, Cement Removal Agent and the Restore → Protect → Maintain programme.
About this guide
Sources
- IEA PVPS Task 13, Soiling Losses: Impact on the Performance of PV Plants (2022), §2.2 on cementation
- Ilse et al., Joule 3:2303–2321 (2019)
- Chemitek, Cement Removal Agent
Show all 18 sourcesShow fewer
- Chemitek, Antistatic Solar Armor 2.0
- Chemitek case study, CRA and ASA, Ecomundo (Chile)
- Chemitek case study, CRA in Dubai (SirajPower)
- Chemitek case study, CRA and ASA, Girasol (Israel)
- Chemitek case study, Solar Wash Protect, Scatec (Honduras)
- Chemitek case study, Solar Wash Protect, Soleden Power (India)
- Chemitek, Cement dust removal and mitigation
- Chemitek, Letters of conformity
- Chemitek, company page (OECD 301F biodegradability testing by CVR)
- Elamim et al., Heliyon (2023), Green Energy Park field trial
- du Plessis et al., IET Renewable Power Generation 14(15) (2020)
- LONGi, O&M Manual V2.0
- Canadian Solar, installation manual appended to its 2020 confirmation letter for Chemitek Solar Wash Protect
- Boshoek Solar environmental management programme, North West (2024), §2.2.3
- RenewChem pilot, North West Province, 24 June 2026 (client unnamed)